Alaris pump module set syringe adapter smallbore slide clamps 2piece male luer lock. Among these is an in line pressure sensor technology, capable of accurate, real time pressure monitoring. The welsh palliative care pharmacists group wpcpg collated information on how syringe drivers were being prescribed across. The disc helps shorten time to alarm, monitor in line pressure and decrease inadvertent bolus following occlusion release.
Flush port home products disposable infusion sets syringe infusion sets. Attach syringe to infusion set and cannula and manually prime the line. Mckinley t34 syringe p or the use of the yringe y cme medical. Bd is a leading manufacturer and provider of safety injection needles and syringes, 1 continually pioneering the development of highquality, easytouse injection devices designed to protect healthcare workers from needlestick injuries and exposure to bloodborne pathogens. Bd, syringes for sale, insulin syringes and diabetic needles. Papertoplastic packaging reduces recycling volume by 50% vs. An all wales syringe driver chart has been developed through the framework set out by the all wales quality and safety sub group, the drug chart reference group. The activated hyperlink may be to a thirdparty website.
Braun perfusor space instructions for use manual pdf. Given the high demand for products in regards to the coronavirus, medline dufort et lavigne states that, as regards selling n95 respirators, masks, protective gowns and disinfecting products alcohol, priority must be given to designated clinics, hospitals and chslds in quebec. Choose syringe and needle technology that makes a difference. These microprocessorcontrolled syringe pumps are designed for applications requiring low, pulsefree flow rates. Teflon or vialon cannulas are associated with less risk of site inflammation than metal butterfly needles8, 9, 11, 12. After priming the line, measure the syringe and document the line change and the time the syringe is calculated to finish. Eta for delivery will take longer than the regular eta.
Gp supplies is the uks premier online store for medical supplies. For instance, your syringe may be marked with a number at every successive ml. They are small in size and the liquid they contain is injected directly into the body. The alaris cc plus syringe pump from bd, delivers exclusive capabilities for significant bedside advantages. The bbraun syringe driver accepts 10ml bd plastipak syringe. However, the size and content of the internal barrel chamber is smaller with the 1ml syringe. Guidelines for setting up and changing the mckinley t34 syringe driver for children receiving palliative care. Than ks jenny fawcett cl inical practice educator the london clinic j. T34 adult syringe driver guidelines harrogate and rural district.
This site writes marketo cookies to help us ensure your correspondence with bd is efficiently directed. The module accepts syringe sizes from 1 to 60 ml, automatically detecting the size. Attach syringe to extension set and manually prime the line. A brief video demonstrating how to insert the saftintima subcutaneous infusion set. This device can be attached to a syringe driver for continuous infusions of prescribed. The niki t34 syringe driver is a small, portable battery operated, programmable, ambulatory syringe pump that delivers the contents of a 2 to 50ml syringe over a specified duration of time or at a given rate in millilitres per hour mlhr.
The alaris pk syringe pump user interface has been developed in cooperation with leading european anaesthesiologists. Setting up a t34 syringe driver lock on prime and load when setting up a syringe driver or renewing the next 24 hour syringe, two qualified nurses should check the drugs, the rate and the identity of the patient 1 initial set up. Effortless transition between hospital and home care requirements is the core of the t34 syringe pump. Bd saftintima line and plug syringe driver universal extension set code. Syringes are available with luer lock, luer slip or eccentric luer tip. Bd syringes for sale insulin syringes diabetic needles. The barrel for a tuberculin syringe is long and thin that can hold up to 1 ml of fluid. Syringe connectors syringes and needles sigmaaldrich. A syringe driver helps reduce symptoms by delivering a steady flow of injected medication continuously under the skin.
Procedure for setting up t34 syringe driver hospital palliative. Bd syringes without needle, 50 ml conventional disposable syringes available without an attached needle. Plymouth hospitals nhs trust battery operated syringe drivers will only be used within. Mckinley t34 syringe p or the use of the yringe y cme. Our range includes medical disposables, medical equipment, pharmaceuticals, surgical nursing and first aid equipment from leading brands like instrapac, instramed, instraspec, comfispec, keeler, welch allyn, omron, smith and nephew, ecolab, clinell and many more. Bd aline syringe with heparin for arterial blood collection bd. The syringe driver is normally used to deliver medications over a 24 hour period to reduce the risk of errors in setting up the device 3, 58. Dec 02, 2016 a syringe driver takes 34 hours to establish a steady state drug level in plasma. Claire britton, specialist nurse practitioner from sobell houses community team, demonstrates how to set up the t34 syringe driver. Alaris syringe driver for windows 7 clicking on the link may allow third parties to collect or share data about you. September 2018 page 4 of 31 palliative care department 2. Feb 04, 2014 a brief video demonstrating how to insert the saftintima subcutaneous infusion set. Clear barrel assures rapid, precise volume reading.
Ensure the syringe is labelled before placing the syringe within the syringe driver. All t34 ambulatory syringe pumps need a sponge pad. Your medicines are put in a syringe, and the syringe driver pushes the medicines through a soft plastic tube and into your body. Additional equipment required community palliative care drug chart. Only use drugs that are known to be effective via the sc route. The plunger can be linearly pulled and pushed along the inside of the tube, allowing the syringe to take in and expel liquid or gas through a discharge orifice at the front open end of the tube. This site writes marketo cookies to help us ensure your correspondence with bd is efficiently. You might have been given a syringe driver, to help control pain, sickness, agitation or fits. Bd syringes without needle, 50 ml gloves, glasses and. Do not place the label over the syringe increments or at the end of the syringe. A syringe driver takes 34 hours to establish a steady state drug level in plasma. All syringes must have a drug label attached nb do not attach the label to the line, the driver or the lock box. Bd aline syringe with heparin for arterial blood collection.
Bd is a leading medical technology company that advances human health in every corner of the world by improving medical research, diagnostics and the delivery of care. All illustrations in this catalogue are only to be used as a guide and do not necessarily depict a true representation of the product. Bdcme issued 2 versions of the field safety notices fsns with actions targeted to the type of healthcare provider. Maxzero needlefree connectors neutraclear needlefree connectors smartsite needlefree connectors maxplus needlefree connectors. Indications for use the t34 syringe driver is designed for infusion of medications or fluids requiring. The syringe and line should be completely changed when the medication. Set up is the same every time and very easy to use. The t34 syringe pump may be used to deliver indicated medications via any common infusion routes including central, peripheral venous, epidural, intraarterial or subcutaneous. Bd syringe with slip tip 20ml, 1ml graduated bd by bd becton dickinson allegro id. Bd leads in health care safety including medication safety, health care worker safety and infection prevention as well as the technologies that enable medical research and. Jun 27, 2019 alaris cc plus syringe pump with guardrails bd. Mckinley t34 syringe driver guidelines for adult supportive. Management of subcutaneous infusions in palliative care. Whilst the preferred route of medication administration in paediatric palliative care is the oral one, there may be occasions when this is impractical or undesirable.
Dispensed volume is continuously displayed, and when the preset volume has been dispensed, these small infusion syringe pumps shut off automatically. Subcutaneous catheter devices management of insuflon and bd. When autoplay is enabled, a suggested video will automatically. T34 syringe driver instruction video for oxfordshire youtube. Braun perfusor space instructions for use manual pdf download. Attach the new line to the bd saf t intima cannula.
Its sometimes called a continuous subcutaneous infusion. These inexpensive pumps combine precision and simplicity with durability. The small, lightweight, ergonomic design ensures the t34 syringe pump is easily portable to improve patient mobility and maintain independence. Sep 05, 2018 alaris syringe driver for windows 7 clicking on the link may allow third parties to collect or share data about you. The t34 syringe pump features a large user interface which clearly displays messages and instructions for an improved user experience.
The bd 1ml luer lock syringe has an almost identical external barrel diameter to the bd 3ml syringe. Incorrect selection of syringe type from the syringe menu may result in significant errors in drug delivery article pdf available in anaesthesia and intensive care 424. T34 syringe pump 3rd ed directions for use instructions for use. A syringe is a simple reciprocating pump consisting of a plunger though in modern syringes, it is actually a piston that fits tightly within a cylindrical tube called a barrel. This website uses cookies to ensure you get the best experience on our website. The alaris cc plus syringe pump works with the guardrails safety software giving you the power to identify, track and, ultimately, prevent many of the most harmful iv medication errors. Diazepam, chlorpromazine and prochlorperazine are too. Jun 06, 2019 the syringe module uses a unique pressure sensing disc which shortens the time to alarm, accurately monitors in line pressure, reduces delays upon infusion start up and decreases inadvertent bolus following occlusion release. With a mckinley syringe driverpump it is the volume of the infusion fluid that is important as only becton dickinson bd plastipak syringes are recommended.
Cme mckinley t34 syringe pump for palliative care guidelines. The 4 smaller lines between every half ml and ml line each mark 0. In between youll see a midsized line that marks half ml units, like 0. A syringe driver is a small, batterypowered pump that delivers medication at a constant rate throughout the day and night. Browse our line of extension sets syringe infusion products.
Unless otherwise noted, bd, the bd logo and all other trademarks are property of becton, dickinson and company. The alaris syringe module will not be able to differentiate between these two syringe types. The t34 syringe pump is a small, lightweight ambulatory infusion pump which offers flexibility and reliability. A range of accessories that will help patients manage the system. Alaris ad syringe driver download if you do not wish to enable cookies please configure this here. The use of a subcutaneous or intravenous infusion using a syringe driver to deliver medications has certain advantages. The syringe module uses a unique pressure sensing disc which shortens the time to alarm, accurately monitors in line pressure, reduces delays upon infusion start up and decreases inadvertent bolus following occlusion release.
827 1404 780 1339 315 1451 649 939 800 1164 1270 571 4 1043 623 633 512 319 1470 1090 383 856 68 251 51 1463 852 1573 1404 964 1391 161 1462 1464 1572 509 198 732 929 1251 987 653 616 318 1469 502 942 1024 23